pharmaceutical-food-beverage-dairy-sanitary-gauge.png
Case 304 SS, polished
Repeatability 0.25% of full scale
Linearity 0.25% of full scale
Lens 3/16″ thick polycarbonate
Over-range Capability 50% of full scale
Hysteresis 0.25% of full scale
CIP Temperature Limit 250°F (121°C) continuous
SIP Temperature Limit 300°F (149°C) 1 hour, dry
Bourdon Tube 316L SS, welded
Socket 316L SS, welded
Storage Temperature -22°F to 195°F (-30°C to 91°C)
Temperature Effect Less than 0.16% per 10°F (5.5°C) change in process or ambient temperature
Actuating Fill Food grade glycerin standard (Mineral oil, silicone and Neobee-20 optional)
Case Fluid Food grade glycerin standard (Dry, mineral oil, silicone and Neobee-20 optional)
Pulsation Dampening Standard
Re-zero Feature Externally adjustable micrometer pointer
Wetted Parts 316L SS, Ra = 8 microinches
Bezel 304 SS, polished
Ambient Temperature 40°F to 140°F (4°C to 60°C)
Process Temperature 0°F to 250°F (-18°C to 121°C)
Accuracy ±0.75% of full scale value